Skip to content
(424) 399-5385
Hillside home with a new standing seam roof, surrounded by dense trees and brush

Fire-Resistant Metal Roofing in Pacific Palisades

For many Palisades families the roof is now a fire question first. This page explains what fire-resistant metal roofing in Pacific Palisades can and cannot do, what California requires, and how a standing seam roof fits into a rebuild.

Call (424) 399-5385 Request an estimate

Built by Eclipse Metal Roofing: custom-fabricated in our Van Nuys shop, installed by our own crew. CSLB #888710.

01

The Palisades Fire, and Why the Roof Question Changed

The Palisades Fire started on January 7, 2025. According to the CAL FIRE incident record, it burned 23,448 acres and destroyed 6,845 structures, with 975 more damaged, before it was contained on January 31, 2025. Behind those numbers are neighbors, schools, churches and businesses, and families who lost their homes.

We are not going to use that loss to sell roofs. What we can do is be useful to the people now making decisions about rebuilding or protecting a home that is still standing. A big part of that is being honest about what fire-resistant metal roofing in Pacific Palisades does, what it does not do, and what the rules require.

Palisades Fire, CAL FIRE incident record: started January 7, 2025; 23,448 acres; 6,845 structures destroyedJan 7, 202523,4486,845Fire startedAcres burnedStructures destroyedSource: CAL FIRE incident record, Palisades Fire.

02

What a Roof Can and Cannot Do in a Wildfire

Homes in a wildfire are exposed in three main ways: direct flame, radiant heat, and embers. Embers are carried by the wind well ahead of a fire front and land on and around houses. Fire research and California's own guidance point to embers as a major cause of home ignitions.

A roof is the largest surface on the house that faces those embers. A roof covering that does not burn, installed as a tested assembly with its edges and openings closed, removes one of the main places where embers can catch. That is the real case for metal: the covering is noncombustible, and a standing seam system can be built as a Class A assembly.

But a roof is not the whole house. Embers also get in through attic and foundation vents, collect in gutters full of dry leaves, lodge against wood fences and decks, and find open eaves. A fire-resistant metal roof in Pacific Palisades is one part of a house that is hardened as a whole. Anyone who tells you a roof alone makes a house safe is overselling it.

03

Class A, Explained

Roof coverings are classified for fire performance under two equivalent standard tests, ASTM E108 and UL 790. The tests look at how well the roof resists fire coming from outside: flame spreading across the surface, burning brands landing on it, and fire getting through to the deck. Class A is the highest classification, then B, then C.

The key point is that the classification belongs to an assembly. The test is run on a specific roof covering, over a specific underlayment, on a specific deck. Some metal roof coverings are Class A only when installed over a particular underlayment or deck. That is why California's rules say the roof has to be installed in accordance with its listing and the manufacturer's instructions.

The standing seam systems we install are specified to meet a Class A rating as an assembly. Our scope names the assembly, so you and the inspector know exactly what is being built.

04

What California Requires in Very High Fire Hazard Severity Zones

California maps Fire Hazard Severity Zones, and the Office of the State Fire Marshal publishes the maps and a zone viewer. Inside the City of Los Angeles, much of Pacific Palisades is mapped as a Very High Fire Hazard Severity Zone. You can check your own parcel on the City's ZIMAS parcel map.

For buildings in those zones, California's wildfire construction standards set the rules for exterior materials. For years they lived in Chapter 7A of the California Building Code and Section R337 of the California Residential Code. The 2025 code cycle moves them into a standalone California Wildland-Urban Interface Code. Your architect and the plan checker will confirm which edition applies to your permit. Across these versions, the roof provisions have been consistent:

  • Class A roof assemblies for new roofs, and for re-roofs as the rules define them.
  • Installation per the listing and the manufacturer's instructions.
  • Gaps closed. Where a roof profile leaves a space between the covering and the deck, such as at the eaves and ridges of a profiled panel, the space has to be closed or fire-stopped to keep flames and embers out.
  • No wood shakes or shingles in fire hazard severity zones.
  • Related rules covering vents, gutters, eaves and other exterior parts of the house.

Paints and coatings do not count as fire protection under these rules. The protection has to come from the materials and how they are put together.

Layers of a standing seam roof: deck, underlayment, clip and panelPanel with raised seamsConcealed clipUnderlaymentSolid deckA roof is an assembly, not just a panelA Class A rating belongs to the tested combination of all four layers.
A Class A rating belongs to the whole tested assembly, installed per its listing.

05

How We Build Fire-Resistant Metal Roofing in Pacific Palisades

The parts of a standing seam roof that matter most for fire are the ones you do not see from the street.

  1. The listed assembly. We specify the panel, underlayment and deck combination that carries the Class A classification, and we install it the way the listing describes.
  2. Closures at the eaves and ridge. Standing seam leaves openings at the panel ends. We close them with closures that keep embers out, as the rules require.
  3. Valleys and gutters. Valleys and gutters collect leaves and needles, and dry debris is exactly what embers ignite. We size valley pans for cleaning and plan gutter protection with the roof.
  4. Roof vents. Any vent through the roof has to meet the ember-resistance rules. We coordinate vent products with your plans and the code.
  5. Walls and edges. Flashings at walls, chimneys and parapets are metal and shop-formed to fit tightly.

All of it is formed in our own Van Nuys shop and installed by our own crew. No subcontractors, ever.

06

Rebuilding After the Palisades Fire

If your home was lost, you are probably working with an architect, an engineer and a general contractor. The roof is one of many decisions, and it is easier to get right early.

The City's Rebuild Options

Pacific Palisades is part of the City of Los Angeles, so rebuild permits run through City Planning and the Department of Building and Safety. The City has issued emergency executive orders to speed rebuilding. According to the City Planning Palisades rebuild FAQ (January 2026):

  • Emergency Executive Order 1 provides a like-for-like rebuild option, allowing up to a 10% increase in the previous building's height and footprint, with no Coastal, Environmental or Mello Act review for projects that qualify.
  • Emergency Executive Order 8 provides a zoning-compliant option for single-family homes in the Coastal Zone that meet its criteria, including bluff setbacks.
  • The City runs the LA One-Stop Rebuilding Center, listed in that FAQ at 1828 Sawtelle Blvd. Hours and processes change, so check the City's recovery website for current details.

The same FAQ notes that LADBS keeps archived plans for single-family homes built after 1978, which can help establish what existed before the fire. For a roofer, those plans are also useful: they show the old roof geometry, which is a starting point for the new one.

Like-for-Like Is About the Building, Not the Old Materials

A like-for-like rebuild is about size, height and location. It does not mean rebuilding with the same roof covering. The new roof still has to meet the wildfire construction rules that apply to your permit. In a Very High Fire Hazard Severity Zone, that means a Class A roof assembly, and many owners are choosing noncombustible standing seam to meet it.

Where We Fit In

  • During design. We can review roof plans and point out where pitch, low-slope sections, parapets or skylights affect which standing seam profiles fit.
  • For the bid. We give your general contractor or you a written scope that names the Class A assembly, metal, finish, closures, flashings and vents.
  • On site. We schedule with your builder, form panels to the framed roof, and install with our own crew.

07

For Homes That Are Still Standing

Many homes in and around the burn area survived, some with damage. If yours is standing and you are thinking about changing to a noncombustible roof, it is a re-roof like any other: tear-off, deck inspection, a Class A assembly and an LADBS permit. The steps are on our metal roof replacement page.

If your home went through smoke and heat, ask your insurer and your contractor to check the roof and attic closely. Damage to underlayment, vents and flashings is not always visible from the ground.

08

Beyond the Roof

A fire-resistant roof works best on a house where the rest of the outside has been thought through too. California's Ready for Wildfire program, run by CAL FIRE, has practical guidance on hardening a home and keeping the area around it clear. Common steps include ember-resistant vents, enclosed eaves, keeping gutters and roof valleys clear of debris, and keeping combustible material away from the walls.

We focus on the roof. If you want to talk through the roof for your home or your rebuild plans, call us at (424) 399-5385. You can also read about the wider company on EclipseMetalRoofing.com.

Questions

Fire, Code and Rebuild Questions

Is a metal roof fireproof?

No roof is fireproof. Metal is noncombustible, so the roof covering itself does not burn, and a properly built standing seam roof can be part of a Class A assembly. But homes are also exposed through vents, gutters, eaves, windows, decks and what is planted or stored near them. The roof is one part of a fire-resistant house.

What does Class A mean?

Class A is the highest fire classification for roof coverings under the standard tests, ASTM E108 and UL 790. The rating belongs to the tested assembly: the covering, the underlayment and the deck as listed. That is why the installation has to follow the listing.

Does California require a Class A roof in Pacific Palisades?

In Very High Fire Hazard Severity Zones, California's wildfire building standards require Class A roof assemblies for new roofs and for most re-roofs. Much of Pacific Palisades is mapped in that zone. Check your own parcel on the City's ZIMAS map, and confirm the requirements for your permit with LADBS.

Can I rebuild with a different roof than the one I had before the fire?

The City's like-for-like rebuild option (Emergency Executive Order 1) is about the size, height and location of the building. The roof covering still has to meet the wildfire construction rules that apply to your permit, which in a Very High Fire Hazard Severity Zone means a Class A assembly. Your architect and LADBS confirm what applies to your project.

When should a metal roofer get involved in a rebuild?

Early, ideally while the roof is being drawn. Roof pitch, low-slope areas, parapets, skylights and solar all affect which standing seam profiles fit. Our page on a standing seam metal roof in Pacific Palisades explains those choices.

Can you replace an existing roof that survived the fire?

Yes. If your house is standing and you want to change to a noncombustible Class A standing seam roof, see metal roof replacement in Pacific Palisades for the process.

Do you install fire-resistant metal roofing near the coast too?

Yes. Lower Palisades streets face salt air as well as fire rules, so metal and finish choices have to satisfy both. See coastal metal roofing in Pacific Palisades.

Estimate

Talk Through Your Roof With the People Who Will Build It

Tell us about the house and what you have in mind. We come out, look at the roof and the access, and give you a written scope for a standing seam roof made in our own shop. There is no pressure and no obligation.

Call (424) 399-5385

Call (424) 399-5385 Estimate